Operating Instructions
© Hydrotechnik GmbH • All rights reserved
Rev. 1.5 / 120816 english
Page 30 of 45
The calculation is CAN, since Patrick sends the data via CAN bus. The variable P stands for particle,
the index is 1 for particle size class ISO 4 µm, what is used as name, too. You have to enter a name
as units, here “SC” (= size class).
Then highlight „Parameter“ and press
to set the CAN parameters like shown here:
All parameters must be defined exactly like shown, otherwise there will be no communication. Specific
for the size class ISO 4 µm are the options „Identifier“ and „Offset“. For ISO size classes you should
enter an identifier resulting from the addition of the Patrick Node-ID (see type plate or Patrick
operation menu) plus 384 (here Node-ID 125: identifier = 125 + 384 = 509). For SAE size classes you
must add 640 to the Patrick Node-ID.
Press
to save the CAN parameters and again to save the settings for channel 8.
Configure channels for further ISO/SAE size classes
This is done in the same way like described for channel 8. Some parameters must be changed for
each size class (IP* = Identifier Patrick, see type plate):
ISO classes
Parameter
4 µm 6 µm 14 µm 21 µm
Channel C8 C9 C10 C11
Index variable 1 2 3 4
Name ISO 4 µm ISO 6 µm ISO 14 µm ISO 21 µm
Identifier IP* + 384 IP* + 384 IP* + 384 IP* + 384
Offset 4 5 6 7
SAE classes
Parameter
4 µm 6 µm 14 µm 21 µm
Channel C8 C9 C10 C11
Index variable 1 2 3 4
Name SAE 4 µm SAE 6 µm SAE 14 µm SAE 21 µm
Identifier IP* + 640 IP* + 640 IP* + 640 IP* + 640
Offset 4 5 6 7