Resistance:
Range Accuracy Resolution:
VC265 VC280
400 Ω ±(1,6% + 3) ±(1,6% + 3) 0.1 Ω
4 kΩ 0.001 kΩ
40 kΩ ±(1,3% + 3) ±(1,3% + 3) 0.01 kΩ
400 kΩ 0.1 kΩ
4 MΩ ±(1,6% + 3) ±(1,6% + 3) 0.001 MΩ
40 MΩ ±(2,0% + 3) ±(2,0% + 3) 0.01 MΩ
Overload protection 600V;
Measuring voltage:
approx. 0.45 V
Capacity
Range Accuracy Resolution:
VC265 VC280
40 nF ±(3,9% + 10) ±(3,9% + 10) 0.01 nF
400 nF 0.1 nF
4 µF ±(3,9% + 5) ±(3,9% + 5) 0.001 µF
40 µF 0.01 µF
100 µF ±(5,2% + 5) ±(5,2% + 5) 0.1 µF
Overload protection 600V
Frequency
Range Accuracy Resolution:
VC265 VC280
10 Hz – 10MHz ±(0,1% + 8) ±(0,1% + 8) 0.001 Hz – 0.01 MHz
Overload protection 600V
Sensitivity ≤1 MHz : 300 mV; Amplitude max. 30 V
Sensitivity >1 MHz : 600 mV; Amplitude max. 30 V
Diode test
Test voltage approx. 1.48 V
Resolution 0.001 V
Overload protection: 600 V
Acoustic continuity tester <10 Ω continuous sound, overload protection 600 V